- VTA96009-00
- 40W AC Adapter
-
- FEATURES
-
- - Mechanically Rugged to withstand Shock
- - Up to 40 Watts Output Power
- - Wide AC Input Range / EMI Filtered
- - Continuous Short Circuit Protection
- - Thermal Protection
-
- This AC Adapter, used in Ground Mobile Military applications, features a low profile package of 9.3Ó L x 6.1Ó D x 1.76Ó H or 0.4Watt/in3. It has excellent load regulation, input filtering, and low output ripple as well as current limiting/thermal shutdown protections.
-
- Input Specifications:
-
- Steady State Input Voltage...................................... 88 to 276 VAC, 1¯
- Steady State Frequency........................................... 47 to 440 Hz
- Voltage Enable........................................................ Between 72VAC and 88VAC
- Voltage Disable....................................................... < 84VAC
- Inrush Current (276VAC @ Full Load) ................. < 2.5 A peak maximum
- Isolation (input/output to chassis) .......................... Hi-Pot Tested @ 300 VDC
-
- Output Specifications:
-
- Nominal Maximum DC Load Ripple Maximum
- Voltage Current Regulation & Noise Power
- + 28 VDC 1.4 A ±7% < 1 Vp-p 40 W
-
- Over-voltage Protection ......................................... 125% of nominal level
- Current Limit .......................................................... >130% of Full Load Current
- Weight.................................................................... ² 6.0 lbs, 2.7 Kg
- Enclosure................................................................ Aluminum Alloy 5052-H32
- Finish...................................................................... Chemical Film per MIL-C-5541, Class 3
- Mounting Position.................................................. Any orientation
- Connections............................................................ Input: NEMA 5-15 Male AC Line Plug
- Output: MS3106A16-11S
- Environmental Specifications:
- Temperature Operating............................................ -20¡C to +60¡C
- Temperature Storage............................................... -35¡C to +80¡C
- Cooling Method...................................................... Conduction cooling via 9.6Ó x 6.0Ó
- mounting surface.
- Humidity................................................................. 95 ± 5% RH non-condensing
- Altitude.................................................................... 15,000 ft
- Shock ..................................................................... 40gÕs, 11 mSec, half-sine pulse, 3 axis
- Vibration................................................................. MIL-STD-810D, Method 514.3, Categories
- 1, 3, and 8.
- EMC/EMI............................................................... CE01, power leads, 30Hz to 15kHz
- ................................................................................ CE03, power leads, 15kHz to 50MHz
- ................................................................................ CE07, power leads, spikes
- ................................................................................ CS01, power leads, 30Hz to 50kHz
- ................................................................................ CS02, power leads, 50Hz to 400MHz
- ................................................................................ CS06, spikes, power leads
- ................................................................................ RE02, electric field, 14kHz to 10GHz
- ................................................................................ RS02, magnetic and elect. fields, spikes
- ................................................................................ RS03, electric field, 14kHz to 10GHz
-
- Reliability:
-
- Predicted Reliability (MIL-HDBK-217F)............... >50.000 Hours
-